TFC-3L Display-unit and switch
for refrigrator
|
||||||||||||||||||||||||||||||||||
| Description: | ||||||||||||||||||||||||||||||||||
| fghgfh | The toggle switch „S” can switch ON and OFF the quickfreezing. The yellow signal lamp „S” indicates the ON state. The red signal lamp „r” indicates the dangerous overheating and the green one „~” the power 230 VAC. | |||||||||||||||||||||||||||||||||
| Protection: | ||||||||||||||||||||||||||||||||||
| The protection is IP40 of the switching unti frontside. If
water enters to the switch-body it can outflow through the buttom hole,
so water can not contact with live circuit. The breakdown and flashover
voltage are more than 3750 V/50 Hz up to one minute, under the following
wet circumstances:
Drop 500cm3 1% NaCl on the endsurface of the display- unit, and cover it with aluminium foil. Connect the test voltage between previously sort circuited terminals and the aluminium foil. Start the test voltage of 3750 V more than the half voltage nad increase quickly up to 3750 V and hold it for 1 minute. ( This test method correspons to the IEC335-1) |
||||||||||||||||||||||||||||||||||
| Technical data: | ||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
| Design variation of front plate | ||||||||||||||||||||||||||||||||||